Wicaksono, Aditya (2018) HUBUNGAN IMPLEMENTASI BUNDLE OF URINARY CATHETER CARE DENGAN KEJADIAN CAUTI DI RSUD SUNAN KALIJAGA DEMAK Studi Observasional Analitik pada pasien di Rumah Sakit Umum Daerah Sunan Kalijaga Demak Periode Bulan Maret-Mei 2018. Undergraduate thesis, Fakultas Kedokteran UNISSULA.

[thumbnail of Cover.pdf] Text
Cover.pdf

| Download (2MB)
[thumbnail of Abstrak.pdf] Text
Abstrak.pdf

| Download (2MB)
[thumbnail of Daftar Isi.pdf] Text
Daftar Isi.pdf

| Download (2MB)
[thumbnail of Daftar Pustaka.pdf] Text
Daftar Pustaka.pdf

| Download (2MB)
[thumbnail of Publikasi.pdf] Text
Publikasi.pdf

| Download (2MB)
[thumbnail of Lampiran.pdf] Text
Lampiran.pdf

| Download (2MB)
[thumbnail of Bab I.pdf] Text
Bab I.pdf

| Download (2MB)
[thumbnail of Bab II.pdf] Text
Bab II.pdf
Restricted to Registered users only

| Download (2MB)
[thumbnail of Bab III.pdf] Text
Bab III.pdf
Restricted to Registered users only

| Download (2MB)
[thumbnail of Bab V.pdf] Text
Bab V.pdf
Restricted to Registered users only

| Download (2MB)
[thumbnail of Bab IV.pdf] Text
Bab IV.pdf
Restricted to Registered users only

| Download (2MB)

Abstract

Background: The insertion of urinary catheter is a cause of Catheter Assosiated Urinary Tract Infection (CAUTI). Catheter Assosiated Urinary Tract Infection has been ranked 2nd in the most common Health Care Associated Infections (HAIs). An action taken to prevent CAUTI is drafting of Guidelines for Prevention and Control CAUTI called Bundle Of Urinary Catheter Care. The aim of study was to determine the relationships between implementation of bundle of urinary catheter care with incidence of CAUTI.
Methods: This study was a observation analytic and methods of sampel uses two paired groups with 32 samples. The study was conducted on adult patients with urine catheter from March to May 2018 in Sunan Kalijaga Hospital Demak. The samples of urine collected on a catheter urine using spuit 5cc.
Results: The results of chi-square test, value of p = 0.040 and correlative coefficient contingency lambda obtained a correlation coefficient r=0.537. The value of Odd Ratio = 13.800(IK95% 4.048-47.050).
Conclusion: From the results is there was a moderate correlation between implementation bundle of urinary catheter care with incidence CAUTI. Patient without bundle had 13.80 times higher risk than to get CAUTI compared to those with guideline implementation.

Keywords: CAUTI (Catheter Assosiated Urinary Tract Infection), Bundle of Urinary Catheter Care, Health Care Assosiated Infections (HAIs)

Dosen Pembimbing: UNSPECIFIED | UNSPECIFIED
Item Type: Thesis (Undergraduate)
Subjects: R Medicine > R Medicine (General)
Divisions: Fakultas Kedokteran
Fakultas Kedokteran > Pendidikan Dokter dan Program Profesi Dokter
Depositing User: Pustakawan Reviewer UNISSULA
Date Deposited: 24 Jun 2019 03:55
Last Modified: 24 Jun 2019 03:55
URI: https://repository.unissula.ac.id/id/eprint/12811

Actions (login required)

View Item View Item